7
C-BUS OUTPUT EVENTS
EXAMPLE 1
For example, if you wanted to program Output Event 1 to turn on
a light (ie, Group 001) for 10 minutes when zone 1 is unsealed
and the 5400/16CB is disarmed.
In installer program mode, press:
P151E 71 1 18 001 010 E
P151E is the PROGRAMMING OPTION for Output Event 1.
71 is the EVENT number for "Zone 1 unsealed when the
panel is disarmed."
1 is the APPLICATION IDENTITY for a lighting application.
18 is the FUNCTION number to pulse ON a light for
aaa minutes.
001 is the GROUP ADDRESS in this example.
010 is the VALUE. In this case 10 minutes.
Press E to fi nish. 3 Beeps will be heard.
C-BUS OUTPUT EVENTS
EXAMPLE 2
For example, if you wanted to program Output Event 2 to do a
20 second ramp of a light to 90% when the 5400/16CB is disarmed.
In installer program mode, press:
P152E 98 1 24 001 090 E
P152E is the PROGRAMMING OPTION for Output Event 2.
98 is the EVENT number for "Panel disarmed."
1 is the APPLICATION IDENTITY for a lighting application.
24 is the FUNCTION number to "20 sec ramp a light".
001 is the GROUP ADDRESS in this example.
090 is the VALUE. In this case 90%.
Press E to fi nish. 3 Beeps will be heard.
INSTALLER'S PROGRAMMING RECORD
NOTES
Output Event
No.
xxx ee A ff iii aaa
Option No.
Event
Identity
Function
Group
Address
Value
1 P151E
2 P152E
3 P153E
4 P154E
5 P155E
6 P156E
7 P157E
8 P158E
9 P159E
10 P160E
11 P161E
12 P162E
13 P163E
14 P164E
15 P165E
16 P166E
Comentarios a estos manuales