Clipsal C-Bus2 Especificaciones

Busca en linea o descarga Especificaciones para Monitores de pantalla táctil Clipsal C-Bus2. Clipsal C-Bus2 Specifications [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 120
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
C-Bus
®
Basic
Training Manual
Volume 2
2A. C-Bus® Toolkit Software
2B. Basic Programming
2C. Advanced Programming
2D. DLT
2E. Network Bridges
2F. Fault Finding
Revision Number: V2
Vista de pagina 0
1 2 3 4 5 6 ... 119 120

Indice de contenidos

Pagina 1 - Volume 2

C-Bus® Basic Training Manual Volume 22A. C-Bus® Toolkit Software2B. Basic Programming2C. Advanced Programming2D. DLT2E. Network Bridges2F. Fault Fi

Pagina 2

C-BUS TRAINING MANUAL - VOL 210ScopeThis manual aims to provide an installer with the basic skills needed to program and useC-Bus®. A fundamental tech

Pagina 3 - Contents Volume 2A. C-Bus

C-BUS TRAINING MANUAL - VOL 2100Another method of connecting to C-Bus® is by the use of a Computer Network Interface (CNI) (Figure 5.1) shows a CNI

Pagina 4

1012E. Network Bridges3.2 Add additional Networks Check that the relevant project is highlighted on the project manager.Press the Add Network button

Pagina 5

C-BUS TRAINING MANUAL - VOL 2102After you have added the Network bridge the following box (Figure 7) will appear which requests you to enter the Seria

Pagina 6 - Contents Volume 2D. DLT

1032E. Network Bridges3.3 Alternative Method Of Adding Additional NetworksAdditional Networks can be added to a project when the bridge is physically

Pagina 7

C-BUS TRAINING MANUAL - VOL 2104Pressing this button will automatically add a Network to the project, this will be seen on the project manager side of

Pagina 8

1052E. Network Bridges4.0 Network Bridge GUIThe Network Bridge GUI is somewhat similar to other C-Bus® GUIs. Unit Identication tab is where detail

Pagina 9 - C-Bus Toolkit Software

C-BUS TRAINING MANUAL - VOL 21064. 1 Connection Tab Figure 15 - Connections Tab 4.2 This Bridge links to Network This option shows which Network the

Pagina 10 - Learning Outcomes

1072E. Network Bridges5.0 Group AddressesIf the Network bridge is configured for two Networks to communicate to each other care should be taken when p

Pagina 11 - 1.2 Operating System

C-BUS TRAINING MANUAL - VOL 2108Given a multistorey building where by master control of a Network is required from a central point, for example secur

Pagina 12 - Installation Package

1092E. Network Bridges

Pagina 13 - 2.1 Starting the Program

112A. C-Bus Toolkit Software1.0 PC RequirementsBefore installing the C-Bus® Toolkit software, ensure your PC meets the requirements below.1.1 Hardwa

Pagina 14 - 3.0 The Menu

C-BUS TRAINING MANUAL - VOL 2110Volume 2FFault Finding

Pagina 15 - 3.1.5 Preferences

1112F. Fault FindingScopeThis manual aims to provide an installer with the basic understanding on how to fault find a basic C-Bus installation.Learning

Pagina 16 - 3.1.8 Exit

C-BUS TRAINING MANUAL - VOL 21121.0 Fault Finding ChartThe intention of this Fault Finding chart is to guide the user in deducing possible installati

Pagina 17 - 3.3 Help Menu

1132F. Fault FindingStartGo back to pg 1.YESNOIs the psysical side working?C-Bus to PC comms OK?Is the correct comms port selected?Select the correc

Pagina 18 - Figure 8 – Project Manager

C-BUS TRAINING MANUAL - VOL 21141.1 Fault Finding NotesNote *1 Checking the Pink cat 5 between C-Bus positive (Blue and Orange) and Negative (Blue/wh

Pagina 19 - 4.1 Project

1152F. Fault FindingNote*5There appears to be no communications coming out of your computer.Check the RS 232 cable possibly the easiest way would be t

Pagina 20 - 4.3 Applications

C-BUS TRAINING MANUAL - VOL 2116Advanced 17Application Addresses 23Backup Project Repository 17Close All Networks 18 Export Projects

Pagina 21 - Icon Function

1172E. Network BridgesIndex Volume 2C. Advanced ProgrammingAND Logic 56Blocks Tab 69Debounce 63Restrike 59Disable All Key

Pagina 22

C-BUS TRAINING MANUAL - VOL 2118Applications 85Blocks tab 87Disable All Keys 86Dynamic Labelling 84Global Tab 86GUI

Pagina 23 - 4.5 Groups

1192C. Advanced ProgrammingIndex Volume 2F. Fault Finding

Pagina 24

C-BUS TRAINING MANUAL - VOL 2122.0 Installing the SoftwareThe C-Bus Toolkit software is available in a .zip file format. This provides smaller file siz

Pagina 25 - 4.7 Units

C1-007O/N 14934CLIPCOM 14934The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted.Product of C

Pagina 26

132A. C-Bus Toolkit Software2.1 Starting the ProgramTo start the C-Bus® Toolkit program click the Windows Start button, navigate to the C-Bus Toolkit

Pagina 27 - 4.8 Topology

C-BUS TRAINING MANUAL - VOL 2143.0 The Menu 3.1.1 Connect to Local RepositoryThis connects to the Toolkit database and C-Bus Networks on the local P

Pagina 28 - Network

152A. C-Bus Toolkit Software3.1.5 PreferencesUse the Preferences panel (Figure 6 and Figure 7) to cony gure various features of the C-Bus® Toolkit.

Pagina 29 - Figure 19 - Default Interface

C-BUS TRAINING MANUAL - VOL 216Advanced Tab Figure 7 - Advanced Tab optionsError ReportingFeedback Log Log commands and errors to a le that can be se

Pagina 30 - Figure 23 - Add new project

172A. C-Bus Toolkit Software3.2 Projects Menu3.2.1 Add ProjectCreate a new empty C-Bus® project. You will be asked if you 'want to add a Networ

Pagina 31 - Figure 24 - Scanned Network

C-BUS TRAINING MANUAL - VOL 2184.0 Using the Project ManagerNOTE: When you first run the C-Bus® Toolkit, you are presented with the “Welcome to C-Bu

Pagina 32 - Figure 25 - Transfer Units

192A. C-Bus Toolkit Software4.1 ProjectWhen first installed, the C-Bus® Toolkit contains two example Projects; “CLIPSAL” and “home”. When a Project

Pagina 33 - is ready to be programmed

C-BUS TRAINING MANUAL - VOL 22© Copyright Clipsal Australia Pty Ltd 2007. All rights reserved. This material is copyright under Australian and interna

Pagina 34 - Basic Programming

C-BUS TRAINING MANUAL - VOL 2204.2 NetworkA Project may contain up to 255 Networks. When a Network is selected the Network window is displayed to the

Pagina 35

212A. C-Bus Toolkit Software Figure 11 – The Applications window is displayed when the Applications folder is selected in the Project ManagerIcon Fun

Pagina 36 - 1.0 Basic Learn Mode

C-BUS TRAINING MANUAL - VOL 2224.4 Individual Application AddressesMany individual Application Addresses (such as Enable Control, Heating and Lightin

Pagina 37 - 1.1 Learn Mode Operations

232A. C-Bus Toolkit Software4.5 GroupsThe Groups folder displays individual Group Addresses that exist in the current Application. When selected, the

Pagina 38 - 1.1.5 Timer Congurations

C-BUS TRAINING MANUAL - VOL 2244.6 Individual Group AddressesMany individual Group Addresses (such as Kitchen, Dining Room or Group 12) may exist in

Pagina 39 - 1.2 Super Learn Mode

252A. C-Bus Toolkit Software4.7 UnitsThis is where the physical C-Bus® units can be viewed and congured. When selected, the “Units in Database” wind

Pagina 40 - 2.0 Voltage Free Relay

C-BUS TRAINING MANUAL - VOL 226Icon FunctionHide Project Manager Hides the Project Manager, providing more room for the Units windows.Add Unit Adds a

Pagina 41 - 3.1 Functions

272A. C-Bus Toolkit Software4.8 TopologyWhen Topology is selected the Topology window is displayed to the right of the Project Manager (Figure 16). F

Pagina 42 - Function Action

C-BUS TRAINING MANUAL - VOL 2285.0 Example: Scanning a New C-Bus® NetworkThis example demonstrates how to scan a new C-Bus® Network.1. Open the C-Bu

Pagina 43 - 4.2 Ambient light

292A. C-Bus Toolkit Software3. You need to select an interface through which to communicate between your PC and the C-Bus® Network (Figure 19)

Pagina 44 - 4.3 Target

3 Scope 10 Learning Outcomes 101.0 PC Requirements 11 1.1 Hardware Requirements 11 1.2 Operating System 112.0 Installing the Softw

Pagina 45 - PIR Occupancy Sensor

C-BUS TRAINING MANUAL - VOL 2306. Once the C-Bus® Toolkit finds a C-Bus Network, it retrieves the Project Name from the PCI or CNI. The defa

Pagina 46 - 5.5 Security Features

312A. C-Bus Toolkit Software 8. The software continues to scan the C-Bus® Network, identifying C-Bus units and adding them to the specie

Pagina 47 - 5.6 Functions Tab

C-BUS TRAINING MANUAL - VOL 2329. It is good practice to keep Databases of Networks that you work with. This has a number of benefits: • The

Pagina 48 - Advanced Programming

332A. C-Bus Toolkit Software10. The Network and database views will now match as shown in (Figure 26). The C-Bus® Network is ready to be programm

Pagina 49

C-BUS TRAINING MANUAL - VOL 234Volume 2BBasic Programming

Pagina 50 - 1.0 Voltage Free Relay

352B. Basic ProgrammingScopeThis manual aims to provide an installer with the basic skills needed to program and useC-Bus®. A fundamental technical ba

Pagina 51 - 1.1 Unit Identification

C-BUS TRAINING MANUAL - VOL 2361.0 Basic Learn ModeThe C-Bus® 2 system features a mode, called Learn Mode, which allows Units on a C Bus Network to

Pagina 52 - 1.2 Logic

372B. Basic Programming1.0.4 Selecting Key InputsOnce the loads have been selected, the user may choose one or more Input Units to control those load

Pagina 53 - 1.3 Turn On

C-BUS TRAINING MANUAL - VOL 2381.1.3 One and Two Key CongurationsThe single key On/Off conguration may be extended so that one key turns the load o

Pagina 54 - 1.4 Recovery

392B. Basic Programmingthe key. If the key is released before the rst double ash, a 5 second timer will be set. This can be useful for testing purpo

Pagina 55 - 1.5 Restrike Delay

C-BUS TRAINING MANUAL - VOL 24Contents Volume 2B. Basic Programming Scope 35 Learning Outcomes 351.0 Basic Learn Mode 36 1.1 Learn Mode Op

Pagina 56 - 1.6 Global

C-BUS TRAINING MANUAL - VOL 2402.0 Voltage Free RelayThis section explains the basic programming of the C-Bus® L5512RVF 12 Channel Voltage Free Relay

Pagina 57 - 1.7 Status

412B. Basic Programming3.0 C-Bus® Wall SwitchThis section explains the basic programming of a 2000 Series Standard C-Bus® Wall Switch. C-Bus input un

Pagina 58 - 2.0 Neo

C-BUS TRAINING MANUAL - VOL 242Function ActionOn Set onOff Set offOn/Off Alternate between set on and offDimmer Dim up or down, according to the dimme

Pagina 59 - 2.2 Global Tab

432B. Basic Programming4.0 C-Bus® Light Level SensorThe C-Bus® Light Level Sensor is a device used to measure ambient light, and transmit messages ov

Pagina 60 - Table 4 – Learn mode options

C-BUS TRAINING MANUAL - VOL 2444.3 TargetThere are two values which determine the level at which the sensor responds to a change in ambient lighting

Pagina 61 - 2.3 Power Fail Tab

452B. Basic Programming5.0 C-Bus® PIR Occupancy SensorCurrently there are three types of C-Bus® PIR Occupancy Sensor; two indoor models and an outdoo

Pagina 62 - 2.4 Key Functions Tab

C-BUS TRAINING MANUAL - VOL 2465.2 Day Time Movement DetectionThis activates a group whenever the ambient lighting level is above the threshold set o

Pagina 63

472B. Basic Programming5.6 Functions TabThe Functions tab (Figure 8) is accessible when the 'Advanced >>' button is used to display t

Pagina 64

C-BUS TRAINING MANUAL - VOL 248Volume 2CAdvanced Programming1C. C-Bus® Hardware

Pagina 65 - 2.5 Blocks Tab

492C. Advanced ProgrammingScopeThis manual aims to provide an installer with the basic skills needed to program and use C-Bus®. A fundamental technic

Pagina 66 - 2.6 Indicators Tab

5Contents Volume 2C. Advanced Programming Scope 49 Learning Outcomes 491.0 Voltage Free Relay 50 1.1 Unit Identication 51 1.2 Logic 52 1

Pagina 67 - 2.6.6 Enable Timer Flash

C-BUS TRAINING MANUAL - VOL 2501.0 Voltage Free RelayWhen editing a unit, the Edit panel displays options in either a Simple or Advanced format. The

Pagina 68 - 2.7 Scenes Tab

512C. Advanced Programming1.1 Unit IdentificationOptions are organised in different categories, and placed on different tabs. The Edit Unit panel in (

Pagina 69 - 2.8 Environment Tab

C-BUS TRAINING MANUAL - VOL 2521.2 LogicThe Logic tab provides more complex functionality. Up to four groups can be logically compared with the chann

Pagina 70 - 2.9 StatusTab

532C. Advanced Programming1.3 Turn OnIn relay units, the Turn On Threshold levels (Figure 3) determine the level at which output units switch on in r

Pagina 71 - 3.0 Scene Control

C-BUS TRAINING MANUAL - VOL 2541.4 RecoveryThe Recovery tab shown in (Figure 4), allows you to set the state that each channel defaults to when recov

Pagina 72 - 3.2 Programming the Neo

552C. Advanced Programming1.5 Restrike DelayThe Restrike Delay is primarily intended for use with lamps that must be allowed to cool down before they

Pagina 73 - 2C. Advanced Programming

C-BUS TRAINING MANUAL - VOL 2561.6 Global Figure 6 – Editing the C-Bus® L5512RVF 12 Channel Voltage Free Relay, with the Global tab selected The Glo

Pagina 74 - Figure 22 – The Scene Manager

572C. Advanced Programming1.7 StatusThe Status tab (Figure 7) displays the status of various device properties. These can be refreshed by clicking th

Pagina 75

C-BUS TRAINING MANUAL - VOL 2582.0 Neo®This section explains the advanced programming options available for the C-Bus® Neo® Wall Switch.2.1 The Unit

Pagina 76

592C. Advanced Programming2.2 Global Tab Figure 9 – Editing a C-Bus® Neo® Wall Switch, with the Global tab selected2.2.1 Debounce The buttons used

Pagina 77

C-BUS TRAINING MANUAL - VOL 26Contents Volume 2D. DLT Scope 79 Learning Outcomes 791.0 Dynamic Labelling Technology Range 80 1.1 Int

Pagina 78 - Dynamic Labelling

C-BUS TRAINING MANUAL - VOL 2602.2.4 Ramp 2This parameter gives the time taken to ramp a light from minimum to maximum brightness (or vice versa), us

Pagina 79

612C. Advanced Programming2.3 Power Fail TabThe Power Fail tab shown in (Figure 10), allows you to set the level that each channel defaults to when r

Pagina 80 - 1.3 About DLT Broadcasting

C-BUS TRAINING MANUAL - VOL 262 2.4 Key Functions TabThe Key Functions tab (Figure 11) provides advanced setup for each wall switch button, allowing

Pagina 81 - 2.0 DLT GUI

632C. Advanced ProgrammingFunction ActionIdle No actionStore 1 This stores the current level in internal the Recall 1 memory location (Blocks tab). Wh

Pagina 82 - 2.1 Global tab

C-BUS TRAINING MANUAL - VOL 264Function ActionRamp Off The output level is ramped to the minimum level and then switched off. The ramp rate is set by

Pagina 83 - 2.2 Blocks tab

652C. Advanced Programming 2.5 Blocks TabThe Block table (Figure 12) displays the operating congureuration of the wall switch. Each row in the table

Pagina 84 - 2.3 Indicators Tab

C-BUS TRAINING MANUAL - VOL 2662.6 Indicators TabThe Indicator tab (Figure 13) provides options which affect the LED indicators on the Neo® unit. Fig

Pagina 85 - 3.1 Labelling Groups

672C. Advanced ProgrammingChange brightness after a button (key) is pressedThis option has several features. When enabled: • The standard LED indicat

Pagina 86

C-BUS TRAINING MANUAL - VOL 2682.7 Scenes Tab Figure 14 – Neo® Scenes Tab The Scenes Tab displays all scenes and the Group Addresses used. Unit stora

Pagina 87 - 3.2 Labelling Scenes

692C. Advanced Programming2.8 Environment Tab Figure 14 – Neo Scenes Tab The Environment tab allows Corridor Linking to be enabled and the necessary

Pagina 88 - 4.0 Setting the Time

7Contents Volume 2E. Network Bridges Scope 91 Learning Outcomes 911.0 Network Bridges Introduction 92 1.1 Capabilities 93 1.2 Li

Pagina 89

C-BUS TRAINING MANUAL - VOL 2702.9 StatusTabThese features (Figure 14) are only available if the Network is open and connected to a PC.The C-Bus® vo

Pagina 90 - Network Bridges

712C. Advanced Programming3.0 Scene ControlThe implementation of scenes has many benefits. At the press of one button, a C-Bus® user has the control o

Pagina 91

C-BUS TRAINING MANUAL - VOL 2723.2 Programming the Neo® Step 1: Open the Neo Unit’s Edit PanelOpen the Edit Panel of the Neo unit to be programmed, b

Pagina 92

732C. Advanced ProgrammingStep 2: Set the Function Type to <Scene>Click on the Function drop down arrow for the Button 1 (Key 1) Group and selec

Pagina 93 - 1.2 Limitations

C-BUS TRAINING MANUAL - VOL 274Step 3: Creating the SceneClick on the properties button. You will be presented with the 'Dene a Scene Button (Ke

Pagina 94 - 1.3 Construction

752C. Advanced ProgrammingGroups are selected from the list on the right and added to the selected scene by clicking on the button that points left. T

Pagina 95 - 2.1 Daisy Chain

C-BUS TRAINING MANUAL - VOL 276In (Figure 24), Scene 1 includes six groups and uses 15% of the memory that is available for that individual scene. Eac

Pagina 96 - 2.2 Star

772C. Advanced ProgrammingStep 4: Saving the SceneClick on the OK button to save the scene. The 'Dene a Scene Button (Key)' panel becomes v

Pagina 97 - 2.3 Combination

C-BUS TRAINING MANUAL - VOL 278Volume 2DDynamic Labelling

Pagina 98 - 3.0 Multi-Network Project

792D. DLTScopeThis manual aims to provide an installer with the basic skills needed to program and use the C-Bus® Dynamic Labelling Technology (DLT) U

Pagina 99 - Figure 6 - Network Details

C-BUS TRAINING MANUAL - VOL 28Contents Volume 2F. Fault Finding Scope 109 Learning Outcomes 109 1.0 Fault Finding Chart 110 1.1 Fault

Pagina 100 - Figure 7 - CNI Network Setup

C-BUS TRAINING MANUAL - VOL 2801.0 Dynamic Labelling Technology Range5055DL C-Bus® Neo® ‘A’ Series DLT (rectangular plate)5085DL C-Bus Saturn ‘A’ Ser

Pagina 101 - 3.2 Add additional Networks

812D. DLT2.0 DLT GUIBefore we get into Languages and Labels, let’s check out the DLT Unit. Select a DLT unit in either view and choose to 'Edit

Pagina 102 - C-BUS TRAINING MANUAL - VOL 2

C-BUS TRAINING MANUAL - VOL 2822.1 Global tabDLT units don’t have infrared but they’ve acquired the ability to have their keys disabled by a Group o

Pagina 103 - 2E. Network Bridges

832D. DLT2.2 Blocks tabThe Blocks tab provides an overview of which groups are assigned to which keys. Figure 4 - DLT Blocks Tab

Pagina 104

C-BUS TRAINING MANUAL - VOL 2842.3 Indicators TabThe “Change brightness after a key is pressed” as seen on a Neo® option has been altered into a &apo

Pagina 105 - 4.0 Network Bridge GUI

852D. DLT3.0 About DLT UnitsDLT Units (Dynamic Labelling Technology) contain a graphical display screen, which can display a label in association wi

Pagina 106 - 4.4 Message Destination

C-BUS TRAINING MANUAL - VOL 286Figure 7 - Labelling DLT GroupsSelect the English Language and Highlight the Lighting application, now press the set de

Pagina 107 - 5.0 Group Addresses

872D. DLT3.2 Labelling ScenesWe will now apply labels to these scenes. As before, navigate to the project manager onto the Network level of the relev

Pagina 108 - 5.1 Copy Tags

C-BUS TRAINING MANUAL - VOL 2884.0 Setting the TimeC-Bus® DLT input units contain a clock. The time is displayed at the base of the display when the

Pagina 109

892D. DLT

Pagina 110 - Fault Finding

92A. C-Bus Toolkit SoftwareVolume 2AC-Bus Toolkit Software

Pagina 111

C-BUS TRAINING MANUAL - VOL 290Volume 2ENetwork Bridges

Pagina 112 - 1.0 Fault Finding Chart

912E. Network BridgesScopeThis manual aims to provide an installer with the basic skills needed to program and useThe C-Bus® Network Bridges. A fundam

Pagina 113 - 2F. Fault Finding

C-BUS TRAINING MANUAL - VOL 2921.0 Network Bridges IntroductionThe C-Bus® DIN Rail mounted Network Bridge, is a Network support device that provides

Pagina 114 - 1.1 Fault Finding Notes

932E. Network Bridges1.1 CapabilitiesThe C-Bus® Network Bridge allows: • Relaying of messages between Networks, to allow all Units on multiple Netw

Pagina 115

C-BUS TRAINING MANUAL - VOL 2941.3 ConstructionThe C-Bus® Network Bridge consists of two functionally and electrically independent systems. Each syst

Pagina 116 - Volume 2B. Basic Programming

952E. Network Bridges2.0 Network Topology The Network topology is the connection scheme between Networks. C-Bus® allows up to 7 Networks in depth (i.

Pagina 117

C-BUS TRAINING MANUAL - VOL 2962.2 Star(Figure 3) illustrates 4 Networks (3 bridges) with minimised depth. No message passes through more than one b

Pagina 118

972E. Network Bridges2.3 Combination(Figure 2) shows a DAISY CHAIN congured Network. Figure 3 shows a STAR congured Network. It should be noted tha

Pagina 119 - Volume 2F. Fault Finding

C-BUS TRAINING MANUAL - VOL 2983.0 Multi-Network ProjectA multi-Network project may be dened at the onset via the Project Manager. Starting a new pr

Pagina 120 - © Clipsal Australia Pty Ltd

992E. Network Bridges3.1 Enter 1st Network Details (Network 254)The details for the new Network will need to be entered. • The Network Name helps i

Comentarios a estos manuales