Clipsal 5400 HomeSafe Security Panel - USER Guide
14
OPERATION
If a detector becomes faulty and cannot be
Sealed when arming the panel, then its zone
may be Excluded so that it does not generate
alarms.
When zones have been Excluded, the EXCLUDE
light flashes continuously while the panel is
Disarmed and also when Armed.
Zones can only be Excluded when the panel is
Disarmed.
Zone Exclude IS not permanent. Excluded
zones are automatically INCLUDED next time the
panel is Disarmed.
Zones can be manually included by the same
method as Excluding. Simply use the
[ZONE NUMBER] sequence to turn OFF the
zone lights to be Included.
NOTES
• EXCLUDE E works only when the panel is Disarmed.
• EXCLUDE [User Code] E works in any state.
• EXCLUDE [User Code] E can only exclude the zones in the Area assigned to that code.